What was found
PHX - DURING C6 INSPECTION, FOUND R1 DOOR THRESHOLD SUPPORT AND INTERCOSTAL CORRODED BEYOND LIMITS AT STATION 344. REPLACED DAMAGED PARTS PER SRM 51-10-00. REFERENCE AWXA9500269.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING C6 INSPECTION, FOUND R1 DOOR THRESHOLD SUPPORT AND INTERCOSTAL CORRODED BEYOND LIMITS AT STATION 344. REPLACED DAMAGED PARTS PER SRM 51-10-00. REFERENCE AWXA9500269.