What was found
DURING A ROUTINE INSPECTION, NOTICED TAIL TIE-DOWN HOOK BROKEN AND SKIN CRUSHED IN THE SAME AREA. THIS CONDITION WAS CAUSED DURING LOADING FREIGHT AND ACFT FALLING ON TAIL. THE CRUSHED REAR BULKHEAD CONTAINS A LIGHTENING HOLE FOR THE ELEVATOR BELLCRANK AND PUSH/PULL TUBE. SLIGHTLY MORE DAMAGE WOULD HAVE INTERFERRED WITH ELEVATOR TRAVEL. SUBMITTER RECOMMENDS OPERATOR NOTIFICATION AND POSSIBLE PLACARD IN THIS AREA.