What was found
ON INSPECTION WHEN REMOVING 76104-08013-101 RETAINER HARDWARE, 2 EACH INSERTS, PN SR 192L, BACKED OUT OF STATIONARY SWASHPLATE. OTHER INSERTS WERE FOUND NOT PROPERLY STAKED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON INSPECTION WHEN REMOVING 76104-08013-101 RETAINER HARDWARE, 2 EACH INSERTS, PN SR 192L, BACKED OUT OF STATIONARY SWASHPLATE. OTHER INSERTS WERE FOUND NOT PROPERLY STAKED.