What was found
CORROSION AT LAP SEAM STRINGER 10 STA 1006 LEFT. OPENED LAP AND CLEANED CORROSION PER SRM 51-10-6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AT LAP SEAM STRINGER 10 STA 1006 LEFT. OPENED LAP AND CLEANED CORROSION PER SRM 51-10-6.