What was found
DURING C-CHECK, FOUND FLOOR TRACK WORN AFT COMP 3 BL 45.500 RIGHT 2 EA PLACES. CUT OUT DAMAGED TRACK. FABRICATED NEW TRACK SECTION IAW DER APPROVED COTNEY ENGINEERING SKETCH SKA 94190-10 AND INSTALLED IAW SRM 53-2-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND FLOOR TRACK WORN AFT COMP 3 BL 45.500 RIGHT 2 EA PLACES. CUT OUT DAMAGED TRACK. FABRICATED NEW TRACK SECTION IAW DER APPROVED COTNEY ENGINEERING SKETCH SKA 94190-10 AND INSTALLED IAW SRM 53-2-3.