As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
UNIT DISASSEMBLED FOR REPLACEMENT OF SEAL AND INSPECT FOR BURRS. UPON INSPECTION, STATOR ASSY HAD ONE-HALF INSTALLED WITH ETCHED SIDE AWAY FROM PLATE. THIS IS IN DIRECT VIOLATION OF PAGE 6, STEP 4 CAUTION NOTE OF DOUGLAS OVERHAUL MANUAL 27-20-5.