What was found
DURING C-CHECK AND C.P.C.P. INSPECTION, FOUND FLOOR BEAM AT BS 344 FROM BL 10R TO BL 45R CORRODED. FABRICATED REPLACEMENT UPPER CHORD FROM BAC1505-100617, 7075-T3 EXTRUSION PER SRM 51-30-5. TREATED AND PRIMED PER SRM 51-10-2. INSTALLED PER SRM 53-10-8.