What was found
DURING INSPECTION OF AD 91-06-06, FOUND STR 19L AT BS 675 EXFOLIATED ON INBOARD LOWER FLANGE. REMOVED DAMAGED AREA OF STRINGER. FABRICATED STRINGER SPLICE FROM BAC 1498-125, 7075-T6 STRINGER MATERIAL AND NEW STRINGER TIE FROM .040 INCH, 7075-T6. TREATED MATERIALS, PRIMED, AND INSTALLED IAW SRM 51-20-1, SRM 53-10-3, SRM 51-10-2, AND SRM 51-30-2.