What was found
DURING 50-HOUR INSPECTION, A SMALL .50 INCH CRACK WAS NOTED ON THE LOWER LEFT ENGINE MOUNT BRACKET OF THE LEFT ENGINE. DYE PENETRANT INSPECTION CONFIRMED THE EXISTANCE OF THE CRACK. DURING ANNUAL INSPECTION 50 HOURS EARLIER, NO CRACKS WERE NOTED ON THIS PORT WHILE COMPLYING WITH AD 94-09-07 AND AD 95-03-14 WHICH REPLACED IT. RECOMMEND BEING SURE TO COMPLY WITH LATEST AD ON THIS BRACKET AND TO VISUALLY INSPECT THE BRACKET ANY TIME WHEN WORKING IN THE AREA.