What was found
DISCOVERED DURING A/C REFURB, VERTICAL PYLON HAS EXCESSIVE CORROSION REQUIRING COMPLETE DISASSEMBLY OF PYLON ASSEMBLY. PARTS WERE CLEANED, TREATED, PRIMED WITH SUPER KOROPON PRIMER AND REASSEMBLED. NO MAJOR PARTS REQUIRED REPLACEMENT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DISCOVERED DURING A/C REFURB, VERTICAL PYLON HAS EXCESSIVE CORROSION REQUIRING COMPLETE DISASSEMBLY OF PYLON ASSEMBLY. PARTS WERE CLEANED, TREATED, PRIMED WITH SUPER KOROPON PRIMER AND REASSEMBLED. NO MAJOR PARTS REQUIRED REPLACEMENT.