What was found
A 3 INCH LONG, .5 INCH WIDE VERTICAL GASH OR PUNCTURE AT STA 530, WL 188, RIGHT SIDE OF FUSELAGE, WAS DISCOVERED DURING THE WALK-AROUND INSPECTION IN SAIPAN. DAMAGE REPAIRED IAW SRM 53-30-3, BLIND RIVET REPAIR. PATCH CONSISTED OF A 9 INCH BY 12 INCH AREA SCARF WITH A CENTER AREA OF 1.5 INCH BY 4 INCH. PATCH MATERIAL USED WAS TT 2024.050.