What was found
RIGHT FUSELAGE IS CHAFED WHERE UNDER WING PANEL SEALS RUB ON FUSELAGE. LOCATED BETWEEN FRAME 32 AND FRAME 33A ABOVE CABIN WINDOWS. SSI NR 53-20-159D. INSPECTED AND BLENDED OUT, ALCROMED AND REPRIMED. PERFORMED EO E92/045/653. ORIGINAL REVISION GENERATED WORK CARD FOR CHAFE OVER FRAME 33 THAT RUNS FORE AND AFT AT .003 INCH FOR 7.50 INCHES (REF W/C 6014) AND REF W/C 6016 FOR ND.