SDR 95ZZZX4142

Service difficulty report · Iso Valve · Bag BAE146200A

Difficulty date
May 18, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N609AW
Make and model
Bag BAE146200A
Aircraft serial
E2070
Part
Iso Valve
Part number
HTE9531101
Condition
Failed
Location
Left Engine
Part time
15,264 hours
Stage of operation
CR
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ORD - FLT 372 - YELLOW HYDRAULIC HI-TEMP WARNING LIGHT CAME ON, 25 MINUTES INTO FLIGHT, LIGHT WENT OUT APPROXIMATELY 10 MINUTES LATER. REMOVED AND REPLACED LEFT ENGINE HYDRAULIC PUMP ISO VALVE. OPS AND LEAK CHECK GOOD. S/N OFF 785VB137. S/N ON 1185VB154.