SDR 95ZZZX5546

Service difficulty report · Pump · Rkwell NA26540

Difficulty date
September 13, 1995
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N311NT
Make and model
Rkwell NA26540
Aircraft serial
282019
Part
Pump
Part number
2017002
Condition
Failed
Location
Fuel Boost
Component
Trw
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PUMP WAS REMOVED FROM AIRCRAFT WITH 52.0 HOURS TIME IN SERVICE SINCE OVERHAUL DUE TO INTERNAL FAILURE CAUSING BOOST PUMP CIRCUIT BREAKER TO TRIP AND WOULD NOT RESET. PUMP WAS OVERHAULED BY REPAIR STATION NR NAXR577E ON 7-12-95 UNDER WORK ORDER NR L3211. SUBMITTER STATES THESE PUMPS ARE 2,000 HOUR TIME-CHANGE ITEMS, BUT LOW-TIME FAILURES SUCH AS THIS ARE COMMON IN FLEET OF 17 AIRCRAFT. AIRCRAFT TOTAL TIME: 13,134.4 HOURS. LANDINGS: 13,400.