What was found
FLOOR PANEL RECEIVED WITH TWO UPPER SKINS OF .020 INCH EACH. SB REQUIRED SKIN OF .020 INCH PANEL. SHOWS HEAVY CORROSION. PART PREVIOUSLY OVERHAULED BY ANOTHER REPAIR STATION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR PANEL RECEIVED WITH TWO UPPER SKINS OF .020 INCH EACH. SB REQUIRED SKIN OF .020 INCH PANEL. SHOWS HEAVY CORROSION. PART PREVIOUSLY OVERHAULED BY ANOTHER REPAIR STATION.