What was found
PERFORMING SB 205B, EDDY CURRENT CHECK OF THREADS IN HUB FOR BLADES, INDICATION WAS A CRACK. VISUALLY SAW A SCRATCH. EXCEPT IN ONE AREA, IT WAS SLIGHTLY OPEN.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PERFORMING SB 205B, EDDY CURRENT CHECK OF THREADS IN HUB FOR BLADES, INDICATION WAS A CRACK. VISUALLY SAW A SCRATCH. EXCEPT IN ONE AREA, IT WAS SLIGHTLY OPEN.