What was found
SUPPLEMENTAL SDR - 1-20-95. ISN - ON APPROACH, ELEVATOR TRIM CABLE SNAPPED. AN UNEVENTFUL LANDING WAS ACCOMPLISHED. MAINTENANCE IS INVESTIGATING THE FAULT. IN RE ELEVATOR TRIM TAB CABLE BREAK. MAINTENANCE INSPECTED ENTIRE CABLE RUN AND FOUND THE BROKEN CABLE HAD BEEN RUNNING OVER RATHER THAN UNDER A CABLE GUARD. A NEW CABLE WAS PROPERLY INSTALLED, SEVERAL PRECAUTIONARY INSPECTIONS WERE ACCOMPLIHSED, AND A TEST FLIGHT WAS SATISFACTORY. A SPECIAL INSPECTION OF OUR D-MODEL FLEET FOUND NO DEFECTS. NOTE: A SAFETY COMMINIQUE DATED 1-95 WAS ISSUED BY THE MANUFACTURER. AN AD HAD ALSO BEEN ISSUED CONCERNING THIS ISSUE.