SDR 95ZZZX692

Service difficulty report · Attach · Cessna 421B

Difficulty date
January 26, 1995
Submitted
March 26, 2000
Operation
General aviation
Make and model
Cessna 421B
Part
Attach
Condition
Loose
Location
Stab To Fuselage
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING INSPECTION AND LOADING OF HORIZONTAL STABILIZER, STRUCTURAL NOISE IN FORM OF KNOCKS, SNAPPING, AND/OR CREAKING (OUTSIDE OF NORMAL SKIN OIL CANNING EVIDENT ON THIS MODEL A/C) EXISTING IN HORIZ STAB. NOISE HAS BEEN TRACED TO MOVEMENT AT HORIZ. STAB. FRONT SPAR-TO-FUSELAGE ATTACH, NAS 1306-3, BOLTS (2 EACH). BOLT REMOVAL HAS DISCLOSED NO CRACKS IN STRUCTURE TO DATE. IT APPEARS THIS IS A DESIGNED LOOSE FIT JOINT WITH BOLT GRIP THAT IS SLIGHTLY TOO LONG. ADDITION OF ONE WASHER AND RETORQUE OF NUT WILL RESTORE BOLT CLAMP-UP AND RESOLVE PROBLEM.