What was found
EPICYCLIC REMOVED FOR 2,000 HR O/H. ON REMOVAL, FOUND SYSTEM CONTAMINATED WITH LARGE AMOUNTS OF METAL RESULTING IN COMPLETE MGB/OIL PUMP, COOLER REPLACEMENT. NO CHIP LIGHTS EVER ILLUMINATED EVEN THOUGH SYSTEM WAS FUNCTIONAL. METAL REACHING PLUG HAD BEEN GROUND TO FINE PASTE WITH LARGE PIECES RETAINED ABOVE MGB AND IN OIL FILTER. SUBMITTER SUGGESTS SHOULD CONSIDER ADDING CHIP PLUG TO MONITOR EPICYCLIC. RMA NR R004466.