As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING D-CHECK, STATION 1030 FLOOR BEAM TOP FLANGE HAS DRILLED HOLE AT CENTER OF FLANGE 'T' HOLE CONTINUES DOWN LOWER LEG OR WEB OF BEAM APPROXIMATELY .75 OF AN INCH. FABRICATED REPAIR PARTS PER SRM 53-10-8 AND 51-40-2. INSTALLED PARTS PER SRM 53-10-8. TOTAL CYCLES 29577.