What was found
DURING D-CHECK, AFT CARGO, SURFACE CORROSION ON INTERCOSTAL LOWER FLANGE BETWEEN STRINGER 29R AND STRINGER 28R BETWEEN FS 1150 AND FS 1170. REMOVED CORROSION PER SRM 51-10-6, TREATED AND PRIMED PER SRM 51-10-2, INSTALLED WEB REPAIR AT PREVIOUS CRACK PER SRM 51040-2, INSTALLED INTERCOSTAL PER SRM 51-30-2. TOTAL CYCLES 29,577