What was found
DURING D-CHECK, AFT CARGO, SURFACE CORROSION AROUND NUT PLATES AT LOWER SURFACE OF FLOOR SUPPORT ANGLES AT FS 1170 LBL 5 AND RBL 8. REMOVED CORROSION PER SRM 51-10-6 AND FOUND OUT OF LIMITS. INSTALLED ANGLE REPAIR PER SRM 51-40-4, MAT USED .050 2 INCHES BY 8 INCHES RBL 8 (.004 REMOVED LBL 5). TOTAL CYCLES 29,577.