What was found
DURING D-CHECK, AFT CARGO, CORROSION AT SEVERAL AREAS IN STRINGER 30 CHANNEL BETWEEN FS 1050 AND FS 1070. REMOVED CORROSION PER SRM 51-10-6. CUT OUT DAMAGED AREA AND FABRICATED PART PER SRM 53-10-3 2 INCHES .71 7075-T62 AND 12 INCHES .90 7075-T62, TREATED AND PRIMED PER SRM 51-10-2. TOTAL CYCLES 29,577.