SDR 9602059880

Service difficulty report · Pt2 Probe · Doug DC951

Difficulty date
January 25, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N675MC
Make and model
Doug DC951
Aircraft serial
47651
Part
Pt2 Probe
Condition
Iced Up
Location
Lt/Rt Engines
Stage of operation
TO
Nature of condition
O
Precautionary procedure
C, D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EPR INDICATION LOW ON BOTH ENGINES DURING TAKEOFF. THE TAKEOFF WAS ABORTED AND THE FLIGHT RETURNED TO THE GATE. MAINTENANCE CLEARED ICE DEPOSITS FROM BOTH PT2 PROBES. ENGINE INDICATION RETURNED TO NORMAL ON SUBSEQUENT RUNUP.