What was found
DURING PERIODIC CHECK, FOUND FLOOR BEAM FLANGE AT STA 1210 - STA 1260 CORRODED BEYOND SRM LIMITS. REMOVED CORROSION AND INSTALLED DOUBLER PER SRM 53-10-01 AND EA 67-99581.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING PERIODIC CHECK, FOUND FLOOR BEAM FLANGE AT STA 1210 - STA 1260 CORRODED BEYOND SRM LIMITS. REMOVED CORROSION AND INSTALLED DOUBLER PER SRM 53-10-01 AND EA 67-99581.