What was found
DURING H-CHECK, FOUND THAT INADEQUATE FORCE WAS REQUIRED TO PULL THE INTERIOR TAIL CONE HANDLE FROM THE CLIPS AND EXCESSIVE FORCE WAS REQUIRED TO DROP THE TAIL CONE, SAME HANDLE. ADJUSTED THE CLIPS AND THE RELEASE SYSTEM PER MM 53-50-3, CHECKED OK.