What was found
DURING APPROACH INTO HOU, NOSE LANDING GEAR GREEN LIGHT DID NOT ILLUMINATE AFTER GEAR WAS EXTENDED. RECYCLED GEAR AND NORMAL INDICATIONS WERE ACHIEVED. MAINTENANCE REPLACED NOSE LANDING GEAR LOCK SWITCH, OPERATIONAL CHECK NORMAL. AIRCRAFT RETURNED TO SERVICE.