SDR 9615499955

Service difficulty report · Elect Control · Doug DC931

Difficulty date
July 15, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N922RW
Make and model
Doug DC931
Aircraft serial
47182
Part
Elect Control
Part number
SYLZ9885
Condition
Malfunctioned
Location
Anti-Ice
Part time
50,935 hours
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT ICE PROTECTION TEMPERATURE HIGH LIGHT ILLUMINATED AFTER TAKEOFF. AIRFOIL ICE PROTECTION PRESSURE ABNORMAL LIGHT ALSO ILLUMINATED. FLIGHT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. MAITNENANCE REPLACED RIGHT ANTICIPATOR AND THERMOSTAT WITH NO HELP. REPLACED RIGHT ELECTRONIC THERMAL CONTROL UNIT. OPERATIONAL CHECK NORMAL. AIRCRAFT RETURNED TO SERVICE.

More about the Doug DC-9-31