What was found
DURING T-CHECK, FOUND CORROSION AND A SHEARED BOLT IN THE 4L DOOR CUTOUT SPLICE FS 1851 AT LONGERON 15L. REPLACED BOLT PER SRM 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING T-CHECK, FOUND CORROSION AND A SHEARED BOLT IN THE 4L DOOR CUTOUT SPLICE FS 1851 AT LONGERON 15L. REPLACED BOLT PER SRM 51-31-01.