What was found
DURING H-CHECK, FOUND CRACKS IN BOTH THE LEFT AND RIGHT SIDE FS 1167 FLOOR BEAM TO FRAME FITTINGS. REPLACED FITTINGS PER SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING H-CHECK, FOUND CRACKS IN BOTH THE LEFT AND RIGHT SIDE FS 1167 FLOOR BEAM TO FRAME FITTINGS. REPLACED FITTINGS PER SRM 51-30-5.