What was found
AT C-CHECK, FOUND BULGING UNDER RAIN GUTTER AT BOTH SIDES OF SEAM STA 1430 WL 259 EXT RT SIDE. CUT OUT DAMAGED SKIN, FABRICATED FILLER 3 BY 4 FT, DOUBLER 6 BY 3 FT; FILLER 2 BY 3 FT AND DOUBLER 4 BY 6, INSTALLED PER SRM 55-30-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FOUND BULGING UNDER RAIN GUTTER AT BOTH SIDES OF SEAM STA 1430 WL 259 EXT RT SIDE. CUT OUT DAMAGED SKIN, FABRICATED FILLER 3 BY 4 FT, DOUBLER 6 BY 3 FT; FILLER 2 BY 3 FT AND DOUBLER 4 BY 6, INSTALLED PER SRM 55-30-3.