What was found
AFT AIRSTAIRS VERTICAL FIN FRONT SPAR FORGING APPROX FS 1195 HAS CRACK INDICATIONS IN RADIUS OF LOWER FLANGE EXTENDING APPROX 3 INCHES TO THE RIGHT OF SPLICE PLATE AT 6 O'CLOCK. STOP DRILLED CRACK. HFEC INSPECTION CONFIRMED CRACK ENDS AT STOP HOLE. FABRICATED AND INSTALLED .125 INCH, 15 INCH BY 15 INCH REPAIR ANGLE, PER AVITAS ENGINEERING ORDER NR 96PMSI 114RO-1.