What was found
TOP SURFACE OF FLOORBEAM AT STA 344 CORRODED IN NUMEROUS AREAS FROM LBL 52 TO RBL 38. INSTALLED DOUBLER REPAIR ON TOP CAP OF FLOORBEAM PER DRAWING SR 27-53-007 FROM FEDEX STANDARD REPAIR DRAWING.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TOP SURFACE OF FLOORBEAM AT STA 344 CORRODED IN NUMEROUS AREAS FROM LBL 52 TO RBL 38. INSTALLED DOUBLER REPAIR ON TOP CAP OF FLOORBEAM PER DRAWING SR 27-53-007 FROM FEDEX STANDARD REPAIR DRAWING.