What was found
INTERCOSTAL BETWEEN BS 1130 AND 1149 HAS FASTENER PULLED THROUGH STR 6R. CUT OUT STR DAMAGE AREA FABRICATED STR SPLICES REPAIR AND INSTALLED REPAIR PARTS WITH FASTENERS PER FEDEX SRM 53-10-3 FIG 3 AT BS 1130 AND 1149 STR 6R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INTERCOSTAL BETWEEN BS 1130 AND 1149 HAS FASTENER PULLED THROUGH STR 6R. CUT OUT STR DAMAGE AREA FABRICATED STR SPLICES REPAIR AND INSTALLED REPAIR PARTS WITH FASTENERS PER FEDEX SRM 53-10-3 FIG 3 AT BS 1130 AND 1149 STR 6R.