What was found
DOUBLE AND TRIPLE HOLES IN FRAME STA 1030 BETWEEN STR 8 AND 9R. ***S/D *** ACCESSED AREA, TRIMMED OUT DAMAGED AREA, FABRICATED DOUBLER, INSTALLED FASTENERS AT BS 130 BETWEEN STR 8 AND STR 9R PER EWO 96-2135.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DOUBLE AND TRIPLE HOLES IN FRAME STA 1030 BETWEEN STR 8 AND 9R. ***S/D *** ACCESSED AREA, TRIMMED OUT DAMAGED AREA, FABRICATED DOUBLER, INSTALLED FASTENERS AT BS 130 BETWEEN STR 8 AND STR 9R PER EWO 96-2135.