What was found
DOUBLE AND TRIPLE HOLES IN FRAME STA 1030 BETWEEN STR 8 AND 9 RT. ACCESSED AREA, TRIMMED OUT DAMAGED AREA, FABRICATED DOUBLER AND INSTALLED FASTENERS AT BS 1030 BETWEEN STR 8 AND 9 RT PER EWO NR 96-2135.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DOUBLE AND TRIPLE HOLES IN FRAME STA 1030 BETWEEN STR 8 AND 9 RT. ACCESSED AREA, TRIMMED OUT DAMAGED AREA, FABRICATED DOUBLER AND INSTALLED FASTENERS AT BS 1030 BETWEEN STR 8 AND 9 RT PER EWO NR 96-2135.