What was found
DURING TAKEOFF RETRACTING FLAPS FROM 15 DEGREES TO 5 DEGREES, OUTBOARD FLAPS LEFT AND RIGHT NEEDLES SPLIT BY 2 NEEDLE WIDTHS AND OUTBOARD FLAP INDICATOR STOPPED MOVING. COMPLIED WITH ASYMMETRICAL FLAP CHECKLIST. REPLACED OUTBOARD FLAP POSITION INDICATOR. CHECKED AND CLEANED LEFT OUTBOARD POSITION TRANSMITTER PLUG. FARED FLAPS WITH A HYD SYS AND SAFTIED ALTERNATE FLAP SWITCH OFF. PERFORMED SEVERAL FLAP CYCLES USING STANDARD PROCEDURE. OPS CK GOOD. NO DEFECT NOTED.