What was found
NR 2 ENGINE WOULD NOT RUN HIGHER THAN EPR 1.02, N1 63.0, EGT 260 DEGREES, N2 74.0, AND FUEL FLOW 2950 POUNDS PER HOUR. POSSIBLE FUEL LEAK. ENGINE SHUT DOWN AS A PRECAUTION. FOUND LEAK ON SECONDARY MANIFOLD TUBE. REMOVED AND REPLACED PACKING FOR SECONDARY MANIFOLD, TUBE LEAKED CHECK OK. NEEDS MANIFOLD CHANGE. REMOVED AND REPLACED FUEL MANIFOLD AND SEALS PERFORMED RUN-UP PER JET RUN HANDBOOK. OPS CK NORMAL. LINE P/N 07-72443-0007.