What was found
EXFOLIATION CORROSION ON FLOORBEAM AT FS 344 FROM RBL 14 TO LBL 35. CUT AND SPLICED IN NEW SECTION OF UPPER FLOORBEAM CAP AT FS 344 FROM 14 RBL TO 70 LBL IAW SRM 53-10-8 FIG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EXFOLIATION CORROSION ON FLOORBEAM AT FS 344 FROM RBL 14 TO LBL 35. CUT AND SPLICED IN NEW SECTION OF UPPER FLOORBEAM CAP AT FS 344 FROM 14 RBL TO 70 LBL IAW SRM 53-10-8 FIG 9.