What was found
LEFT GENERATOR FAILED, IDG DRIVE DISCONNECTED ACCOMPANIED WITH INCREASED VIBRATION. *S/D* FOUND INTEGRATED DRIVE GENERATOR FAILED. REPLACED GENERATOR, CHECKS OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT GENERATOR FAILED, IDG DRIVE DISCONNECTED ACCOMPANIED WITH INCREASED VIBRATION. *S/D* FOUND INTEGRATED DRIVE GENERATOR FAILED. REPLACED GENERATOR, CHECKS OK.