What was found
STL - DURING SPECIAL INSPECTION, FOUND .5 INCH CRACK LONGERON 5R STATION 756, REPAIRED PER SRM 53-02 FIGURE 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STL - DURING SPECIAL INSPECTION, FOUND .5 INCH CRACK LONGERON 5R STATION 756, REPAIRED PER SRM 53-02 FIGURE 2.