FOUND LEVEL 2 CORROSION, FLOOR BEAM STATION 1778 FROM BL 82 LEFT AND RIGHT CORRODED. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 53-21-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND LEVEL 2 CORROSION, FLOOR BEAM STATION 1778 FROM BL 82 LEFT AND RIGHT CORRODED. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 53-21-00. (M)