What was found
LEVEL 2 CORROSION, CORROSION AT STRINGER 34R BETWEEN STATION 1190 AND 1200 INSIDE OF C-3 CARGO. REMOVED CORROSION TREATED AND PRIMED AREA. INSTALLED NEW FITTING PER SRM 53-2-0. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION, CORROSION AT STRINGER 34R BETWEEN STATION 1190 AND 1200 INSIDE OF C-3 CARGO. REMOVED CORROSION TREATED AND PRIMED AREA. INSTALLED NEW FITTING PER SRM 53-2-0. (M)