What was found
LEVEL 2 CORROSION, LOWER END OF NR 2 VERTICAL STABILIZER LEADING EDGE CAP IS CORRODED. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 55-2-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION, LOWER END OF NR 2 VERTICAL STABILIZER LEADING EDGE CAP IS CORRODED. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 55-2-1. (M)