As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STATION 420 RBL 10 INCHES TO 60 INCHES OF LEVEL 2 CORROSION ON UPPER SURFACE OF FLOOR SUPPORT. ALSO, SMALL SECTION OF R1 GALLEY DOOR FLOOR STRUCTURE AT STA 420 HAS LEVEL 2. REMOVED AND REPLACED FLOOR SUPPORTS PER SRM 53-10-2, 51-10-2, 51-30-2. (M)