What was found
LEVEL 2 EXFOLIATING CORROSION OF FLOOR SUPPORT AT STATION 312 CBL TO LBL 20 INCHES. CUT OUT DAMAGED AREA ON AFT SIDE OF 'T', FABRICATED AND INSTALLED REPAIR ANGLES, STRAPS AND FILLERS IAW SRM 51-40-4 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 EXFOLIATING CORROSION OF FLOOR SUPPORT AT STATION 312 CBL TO LBL 20 INCHES. CUT OUT DAMAGED AREA ON AFT SIDE OF 'T', FABRICATED AND INSTALLED REPAIR ANGLES, STRAPS AND FILLERS IAW SRM 51-40-4 FIG 1. (M)