What was found
MAIN CABIN CRACK IN FLOOR BOARD ATTACH ANGLE AT STATION 1130 RBL 64. ALSO, SMALL AREA OF LEVEL 1 CORROSION 6 INCHES FARTHER AFT FROM CRACK. REMOVED CORROSION, MATERIAL LOSS WITHIN ACCEPTABLE LIMITS PER SRM 51-10-6, 51-10-3 AND FABRICATED ANGLE DOUBLERS, ALODINE AND PRIMED PER SRM 51-10-2 AND 51-40-4. INSTALLED ANGLE DOUBLERS PER SRM 51-40-4 FIG 3. (M)