As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING D-CHECK, FOUND MCD, BOTTOM OF DOOR INBOARD STRUCTURE JUST BELOW STATION 500 RIB, HAS CRACK INDICATION. REMOVED RIB AND ALUMINUM BLOCK. FABRICATED NEW ALUMINUM BLOCK 7075-T6 .250 3.5 INCHES BY 5.5 INCHES AND INSTALLED. REPLACED SEAL RETAINER 1 INCH BY 12 INCH 2024-T3 .032 AS PER SRM 51-10-1 PAR 4 AND 51-30-2.