What was found
DURING C-CHECK, FOUND STATION 760 RBL 65 FRAME AND SUPPORT ANGLE IS CORRODED LOCATED JUST BELOW FLOOR LEVEL. REMOVED AND REPLACED SUPPORT ANGLE STATION 760 RBL 65 7075 T-6 .100 1 INCH BY 1 INCH BY 3.5 INCH AS PER SRM 51-10-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND STATION 760 RBL 65 FRAME AND SUPPORT ANGLE IS CORRODED LOCATED JUST BELOW FLOOR LEVEL. REMOVED AND REPLACED SUPPORT ANGLE STATION 760 RBL 65 7075 T-6 .100 1 INCH BY 1 INCH BY 3.5 INCH AS PER SRM 51-10-1.