As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK, FOUND FUSELAGE BULGE STATION 740 STRINGER 25L AND CLIP HAVE CORROSION. CLIP WAS REMOVED AND CUT OUT DAMAGED AREA OF STRINGER 25L BS 740 7 INCHES APPROXIMATELY AS PER SRM 53-10-3. REPLACED CLIP PER SRM 51-10-1 PAGE 4. INSTALLED STRINGER REPAIR AS PER SRM 53-10-3 FIG 1 ABOUT 12 INCHES LONG. MATERIAL USED BAC 1498-145 LOT NR 464951.